Sign In | Join Free | My chinalane.org
chinalane.org
Products
Search by Category
Home > Measuring & Analysing Instrument Stocks >

Salt Spray Test Chamber for corrosion testing with 0℃ - 85℃ Room Temperature

Categories Temperature Humidity Chamber
Brand Name: OTS
Model Number: XB-OTS-90
Certification: CE Certification
Place of Origin: China
MOQ: one set
Price: Negotiable
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100 Unit/Units per Month
Delivery Time: 20 working day after getting the payment
Packaging Details: Strong standard wood case, inner plastic films wrapped for Salt spray Corrosion Test Chamber air drying temperature humidity chamber
Model Numbe: XB-OTS-90
Product name: Salt spray Corrosion Test Chamber air drying temperature humidity chamber
Spray Volume: 1.0~2.0ml/80cm2/h
test room temperature: +0℃~+85℃
PH: 6.5~7.2 for Salt Spray Method (NSS ACSS)and 3.0~3.2 for Corrosion-resistant Testing Method(CASS)
Relative humidity: 20%~98%RH(±3%)
material: PVC material
Design standards: IEC68-2-11,JIS,H8502,ASTM B-117-97,ISO9227,CNS3627,3885,4159,7669,8886,JIS D-0201 ,ASTM G85
Safety Protection Devices: Current discharge protection, over pressure protection,over temperature protection, over load fuse protection
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Salt Spray Test Chamber for corrosion testing with 0℃ - 85℃ Room Temperature

    Salt spray Corrosion Test Chamber air drying temperature humidity chamber


    Introduction

    Salt spray Corrosion Test Chamber air drying temperature humidity chamber is applicable for various kinds material’s surface treatment with temperature humidity and salt water spray, such as after coating, electroplate, inorganic and organic membrane dermal, negative pole with antirust oil treatment etc anti-corrosive treatment to test the corrosion-resistance of the product.Can also be used to external lighting and signal device and vehicle lamps shell protection. Walk in type salt spray test chamber is available for us.


    Features:

    1.Automatic / manual water system has automatically add the water level of the water level is low, the test is not interrupted. Water level is insufficient warning to ensure that the use of safety.
    2.Precision glass nozzle (PYREX) made of special glass, mist spread evenly and naturally fall on the specimen, and 4000 hours of continuous use, and to ensure that no crystalline salt obstruction.
    3.Inlet temperature controller using a digital display, PID control, error of ± 0.1 ° C.
    4.Laboratory using direct steam heating, heating up fast, and even reduce the standby time, heating tubes with high corrosion-resistant titanium tubing.
    5.Laboratory basket rack using plane indexing rack, can arbitrarily adjust the angle, four off the fog, and the fog direction completely consistent.


    Specification

    ModelXB-OTS-90XB-OTS-120XB-OTS-160XB-OTS-200
    Interior Test Chamber
    Dimension(cm)(L×W×H)
    90×50×60120×80×50160×100×50200×100×50
    Exterior Test Chamber Dimension(cm)(L×W×H)141*145*140190*165*140200*190*140240*200*140
    Capacity of the chamber(L)270L480L800L1000L
    Temperature&humidity of the operating environment+5°C~ +35°C / <85%RH
    Air pressure86~ 106Kpa
    Lab. temperatureNSS ACSS 35°C±1°C
    CASS 50°C±1°C
    Pressure barrel temperatureNSS ACSS 47°C±1°C
    CASS 63°C±1°C
    Temperature&humidity
    Control Accuracy
    Test room temperature range: +0℃~+85℃Relative humidity: 20%~98%RH(±3%)
    Saturated barrel temperature: 47℃~70℃Temperature/humidity uniformity: ≤±2℃ ≤±3%
    Temperature resolution: 0.01 ℃Humidity Resolution: 0.1% RH
    Temperature fluctuation: ± 0.5 ℃Humidity fluctuation: ± 2% RH
    Cooling system

    A. Air-cooled scaly condenser

    B. Cooling by imported compressor.



    Design Standard:

    GB-T2423.17-1993 Humidity and salt spray test

    GB/T 12967.3-91 CASS test

    ASTM.B117-97 Humidity and salt spray test

    GB/T 10125-2012 Corrosion tests in artificial atmospheres; Humidity and salt spray test

    * GB/T 2423.18-2000 *GB/T 10125-1997 ASTM.B117-97

    *JIS H8502 *DIN50021*JIS Z2371 * IEC68-2-11*QJ 2027-1990

    *IEC68-2-52 1996 *GB.10587-89 *EN 14147*SH/T 0081-1991

    *CNS.4158 * CNS.4159 CASS*GB/T 12967.3-91 CASS

    Thermostatic control can be set under CNS, JIS, ASTM standard:

    Ⅰ Humidity and salt spray test: NSS,ACSS

    1) Temperature of test box: 35℃±1℃

    2) Temperature of pressure bucket: 47℃±1℃

    Ⅱ Corrosion resistance test: CASS

    1) Temperature of test box: 50℃±1℃

    2) Temperature of pressure bucket: 63℃±1℃

    Supply system: the pressure is 1kg/cm²

    Spray measurement 1-2mI(mI/80cm²/h)(average in 16 hours)

    Spray way: Continuously.


    Please feel FREE to contact us if you have any needs.


    Custom-made ASTM B117 NSS AASS CASS Salt fog Cabinet , salt spray test chamber

    Quality Salt Spray Test Chamber for corrosion testing with 0℃ - 85℃ Room Temperature for sale
    Send your message to this supplier
     
    *From:
    *To: Dongguan Xinbao Instrument Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     