Brand Name: HIDIER-Perkins
Model Number: HDP1800/S
Certification: CE, CSA, NOISE, GS, EC-II, EPA, CARB, GOST.
Place of Origin: Perkins Engine, assembled in China
MOQ: 1pcs
Payment Terms: T/T, L/C
Supply Ability: 1000pcs/week
Delivery Time: Within 30 days
Packaging Details: Plywood box
Output Capacity: 2050/2260kVA
Output Power: 1800/1800kW
Genset Type: Hidier
Engine: Perkins
Frequency: 50Hz / 60Hz
Cooling Type: water cooled
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    1800KW Automatic Control Panel Perkins Diesel Generators 4-Stroke

    1800KW Automatic Control Panel Perkins Diesel Generators 4-Stroke



    HDP Series HDP1800/ HDP1800S

    Model

    Standby Power

    Prime Power

    Engine

    Alternator

    Control Panel

    KVA

    KW

    KVA

    KW

    Stamford

    Hidier(Optional)

    Model

    HDP1800/S

    2260

    1808

    2050

    1640

    4016-TAG2A

    PI734F

    HD1640

    MRS10

    Spec #1.1 Features

    1

    Excitation system: self-excited (AREP and PMG are optional)

    2

    ATS (automatic transfer switch) receptacle

    3

    Lockable battery isolator switch

    4

    Stainless galvanized zinc plates with strong corrosion resistance

    5

    Vibration isolators between the engine/alternator and base frame

    6

    Integrated wiring design

    7

    Base fuel tank for at least 8 hours running

    8

    Equipped with an industrial muffler

    9

    50℃ radiator

    10

    Top lifting and steel base frame with forklift holes

    11

    Drainage for fuel tank

    12

    Complete protection functions and safety labels

    13

    IP54 (soundproof sets), IP56 (control system)

    14

    Water jacket preheater, oil heater are available.

    15

    Double air cleaner, spare parts, special tools are available.

    16

    Custom-made is acceptable


    Ratings and Performance Data
    Engine Brand & Model:Perkins 4016-TRG3A
    Alternator Brand & Model:Stamford PI734F
    Control System:ComAp InteliLite®MRS10
    Noise Level@7m:80-95
    Frequency & Phase:50Hz & 3 Phase
    Engine Speed: RPM1500
    Structure Type:HDP1800
    HDP1800S
    Fuel Tank Capacity: LHDP1800/
    HDP1800S/
    Fuel Consumption: l/hr (100% Load)Prime/
    Standby/
    Generator SetLength (L)Width (W)Height (H)Net Weight kg
    Modelmmmmmm
    HDP180058002800350014500
    HDP1800SREQREQREQREQ

    Spec #1.2 Container Calculation

    Generator Set Model

    20’GP

    pcs

    40‘GP

    pcs

    40‘HQ

    pcs

    Efficiency

    HDP1500

    N/A

    N/A

    N/A

    N/A

    HDP1500S

    N/A

    N/A

    N/A

    N/A


    Spec#2 Engine Perkins 4016-TRG3A




    Spec #2.1 General Data

    Number of cylinders

    16

    Cylinder arrangement

    Vee, 60°

    Cycle

    4 stroke

    Induction system

    Turbocharged

    Combustion system

    Direct injection

    Compression ratio

    13.6:1

    Bore and Stroke

    160 x 190 mm (6.3 x 7.5 in)

    Cubic capacity

    61.123 litres

    Direction of rotation

    Anti-clockwise viewed on flywheel

    Cooling system

    Water cooled

    Total coolant capacity

    316 litres

    Total lubrication system capacity

    237.2 litres (62.7 US gals)

    Dimensions

    L4460mm

    W2185 mm

    H2775mm

    Total weight (dry)

    3239 kg

    Spec #2.2 Engine Output

    Speed

    rpm

    Run Type

    Typical Output (Net)

    Engine Power

    Gross

    Net

    kVA

    kWe

    kWm

    hp

    kWm

    hp

    1500

    Prime

    1634

    13071413189413621821

    Standby

    2025

    16461766236717152300

    Standby (maximum)

    2263

    18111937259618862529

    *Subject to conformance with ASTM D6751 and EN14214.

    The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on typical alternator efficiencies and a power factor (cos θ) of 0.8.

    Fuel specification: BS 2869: Part 2 1998 Class A2 or ASTM D975 D2.

    Rating Definitions:

    Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours operation.

    Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.

    Spec #2.3 Fuel System

    Type of injection

    Direct

    Fuel injection pump

    Rotary

    Fuel atomiser

    Multi-hole

    Nozzle opening pressure

    23MPa

    Electronic governor (optional)

    Woodward LCG2

    Fuel lift pump

    type

    Electrical

    flow/hour

    120 - 150 l/h (211 - 264 pt/m)

    pressure

    30 - 75 kPa (4.4 - 10.9 psi) a

    Maximum suction head

    17 kPa

    Maximum static pressure head

    3.0 m

    Governor type

    Woodward LCG2

    Fuel specification

    USA Fed Off Highway - EPA2D 89.330-96

    Europe Off Highway - CEC RF-06-99

    Fuel Consumption

    Engine Speed

    g/kWh

    Litres/hr

    1500

    1800

    1500

    1800

    At Standby Max power

    215

    -

    490

    -

    At Prime Power rating

    210

    -

    436

    -

    75% of prime power

    202

    -

    315

    -

    50% of prime power

    202

    -

    210

    -

    Spec #2.4 Cooling System

    Total coolant capacity

    Engine only

    95 litres

    ElectropaK (engine/radiator)

    316 litres

    Pressure cap setting

    69 kPa

    Fan

    Incorporated in radiator

    Diameter

    1905 mm (pusher)

    Coolant pump speed

    1.4 x e rpm

    Method of drive

    Gear driven

    Maximum static pressure head on pump

    above engine crank centre line

    7 m

    to coolant pump flow

    71-85°C

    Thermostat operating range

    7

    Shutdown switch setting

    101°C rising

    Coolantimmersion heater capacity

    4 kW x 2

    Coolant

    Total system capacity

    -with radiator 10.2 litres

    -without radiator 4.4 litres

    Maximum top tank temperature

    110 °C

    Temperature rise across engine

    82 - 93 °C (180 - 199 °F)

    Max permissible external system resistance

    kPa

    Thermostat operation range

    82 - 93 °C

    Max. static pressure head on pump

    30.4 kPa

    Recommended coolant

    50% anti freeze / 50% water. For complete details of recommended coolant specifications, refer to the

    Operation and Maintenance Manual for this engine model.

    Duct allowance

    Maximum additional restriction (duct allowance) to cooling airflow and resultant minimum airflow

    Ambient clearance 50% Glycol

    Duct allowance Pa

    m³/sec

    N/A

    N/A

    N/A

    N/A

    N/A

    N/A


    Spec #2.5 Induction System

    Maximum static bending moment

    at rear face of block

    1400 Nm

    Maximum air intake restriction

    -clean filter.

    127 mm H2O

    -dirty filter

    380 mm H2O

    -air filter type

    MF&T 5000-00-00

    Spec #2.6 Electrical System

    type

    Insulated return

    alternator

    24 volts with integral regulator

    starter motor

    24 volts

    Starter motor power

    16.4 kW

    Number of teeth on flywheel

    TBA

    Number of teeth on starter motor..

    9

    Minimum cranking speed (0°C)

    126 rpm

    Cold start recommendations

    Minimum engine cranking speed over TDC

    120 rev/min

    Minimum

    starting

    temperature

    Grade of

    engine

    lubricating

    oil

    Battery specifications

    °C

    BS3911

    Cold

    start

    amps

    SAEJ537

    Cold

    cranking

    amps

    Number

    of

    batteries

    needed

    Commercial

    ref number

    0

    20W

    540

    740

    1

    647

    -15

    10W

    540

    740

    1

    647

    -20

    5W

    600

    780

    1

    655


    Spec #2.7 Exhaust System

    4016TAG2A

    673 mm H20

    Exhaust outlet flange size

    2 x 254 mm (table ‘D’

    Emissions statement: Constant Speed Engines for use in Industrial, IOPU and ElectropaK applications: Certified against the requirements of EU Stage IIIA (Directives 97/68/EC, as last amended, for mobile applications).

    Spec #6.8 Lubrication System

    Lubricating oil capacity


    Sump maximum

    214 litres

    Maximum engine operating angles

    front up, front down

    25° continuous

    Lubricating oil pressure

    At 80°C temperature to bearing gallery (minimum)

    0.34 MPa

    Sump drain plug tapping size

    G1

    Oil pump speed and method

    1.4 x e rpm, gear driven

    Oil pump flow

    .6,70 litres/sec

    Normal operating angles

    Front and rear ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. 5°

    Side tilt .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 10°


    Spec#3 Alternator Stamford P1734F

    CONTROL SYSTEM

    SEPARATELY EXCITED BY P.M.G.

    A.V.R.

    MX341

    A.V.R.

    MX341

    VOLTAGE REGULATION

    ± 1%

    VOLTAGE REGULATION

    ± 1%

    SUSTAINED SHORT CIRCUIT

    REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)

    INSULATION SYSTEM

    CLASS H

    PROTECTION

    IP23

    RATED POWER FACTOR

    0.8

    STATOR WINDING

    DOUBLE LAYER LAP

    WINDING PITCH

    TWO THIRDS

    WINDING LEADS

    6

    MAIN STATOR RESISTANCE

    0.00076 Ohms PER PHASE AT 22°C STAR CONNECTED

    MAIN ROTOR RESISTANCE

    2.31 Ohms at 22°C

    EXCITER STATOR RESISTANCE

    17.5 Ohms at 22°C

    EXCITER ROTOR RESISTANCE

    0.048 Ohms PER PHASE AT 22°C

    R.F.I. SUPPRESSION

    BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

    WAVEFORM DISTORTION

    NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%

    MAXIMUM OVERSPEED

    2250 Rev/Min

    BEARING DRIVE END

    BALL. 6232 C3

    BEARING NON-DRIVE END

    BALL. 6319 C3


    1 BEARING

    2 BEARING

    WEIGHT COMP. GENERATOR

    3840 kg

    3807 kg

    WEIGHT WOUND STATOR

    1908 kg

    1908 kg

    WEIGHT WOUND ROTOR

    1609 kg

    1565 kg

    WR² INERTIA

    49.3409 kgm2

    48.424 kgm2

    SHIPPING WEIGHTS in a crate

    3913kg

    3876kg

    PACKING CRATE SIZE

    216 x 105 x 154(cm)

    216 x 105 x 154(cm)


    50 Hz

    60 Hz

    TELEPHONE INTERFERENCE

    THF<2%

    TIF<50

    COOLING AIR

    2.69 m³/sec 5700 cfm

    3.45 m³/sec 7300 cfm

    VOLTAGE STAR

    380/220

    400/231

    415/240

    440/254

    416/240

    440/254

    460/266

    480/277

    kVA BASE RATING FOR REACTANCE VALUES


    2020


    2080


    2080


    2040


    2340


    2500


    2550


    2600

    Xd DIR. AXIS SYNCHRONOUS

    2.93

    2.73

    2.53

    2.21

    3.54

    3.38

    3.16

    2.96

    X'd DIR. AXIS TRANSIENT

    0.18

    0.17

    0.15

    0.13

    0.21

    0.20

    0.19

    0.18

    X''d DIR. AXIS SUBTRANSIENT

    0.13

    0.12

    0.11

    0.10

    0.16

    0.15

    0.14

    0.13

    Xq QUAD. AXIS REACTANCE

    1.89

    1.75

    1.63

    1.42

    2.28

    2.18

    2.03

    1.90

    X''q QUAD. AXIS SUBTRANSIENT

    0.26

    0.25

    0.23

    0.20

    0.32

    0.31

    0.29

    0.27

    XL LEAKAGE REACTANCE

    0.03

    0.03

    0.03

    0.03

    0.04

    0.04

    0.04

    0.03

    X2 NEGATIVE SEQUENCE

    0.19

    0.17

    0.16

    0.14

    0.23

    0.22

    0.20

    0.19

    X0 ZERO SEQUENCE

    0.02

    0.02

    0.02

    0.02

    0.03

    0.03

    0.02

    0.02

    REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED

    T'd TRANSIENT TIME CONST.

    0.154s

    T''d SUB-TRANSTIME CONST.

    0.02s

    T'do O.C. FIELD TIME CONST.

    2.54s

    Ta ARMATURE TIME CONST.

    0.02s

    SHORT CIRCUIT RATIO

    1/Xd


    Spec#4 Control System ComAp InteliLite® MRS10



    Spec #4.1 Features

    1

    Automatic or manual start/stop of the gen-set

    2

    Push buttons for simple control, lamp test

    3

    Lockable battery isolator switch

    4

    Graphic back-lit LCD display 128×64 pixels

    5

    2 LED indicators

    6

    Integrated wiring design

    7

    Parameters adjustable via keyboard or PC

    8

    Generator measurements (50/60 Hz):U1-U3, I1-I3, Hz, kW, kVAr, kVArh, kWh

    9

    Selectable protections alarm/ shutdown

    10

    3 phase Generator protections

    – Over-/under voltage

    – Over-/under frequency

    – Current/voltage asymmetry

    – Overcurrent/overload

    11

    Analog oil pressure, water, temperature, fuel level, battery, voltage, engine speed (pick-up)

    12

    Configurable programmable inputs and outputs

    13

    Warm-up and cooling functions

    14

    RS232 interface (AT-LINK CONV cable is necessary for IL-MRS 10)

    15

    Dimensions 180×120 mm (front panel)

    16

    Sealed to IP65

    17

    Custom-made is acceptable

    Spec #4.2 Functions

    Binary inputs/oupputs

    6/6

    Analog inputs

    3

    Pick-up

    -

    AMF function

    -

    Input configuration

    Output configuration

    Voltage measurement Gen./Mains

    3ph/-

    Current measurement

    3ph

    KW/KWH measurement

    ●/-

    GCB/MCB control with feedback


    Extension units(periph)

    -

    Communication interfaces

    Rs232

    Modem support

    -

    Battery charging alternator circuit

    Spec #5 Options


    Items

    Options

    Select

    Engine

    Water Jacket Preheater


    Oil Preheater


    Alternator

    Winding Temperature Measuring Instrument


    Alternator Preheater


    PMG


    Anti-damp and anti-corrosion treatment


    Anti-condensation heater


    Generator Set

    Tools with the machine

    STND

    Fuel System

    Low fuel level alarm


    Automatic fuel feeding system


    Fuel T-valves


    Enclosure

    Open Type


    Silent/Super Silent Type


    Trailer Type


    Canopy/Enclosure Type


    Lubricating sys

    Oil with the machine


    Exhaust Sys.

    Protection board from hotness


    Cooling Sys.

    Front heat protection


    Coolant (-30°C)


    Control System

    Remote Control System


    ATS Control System


    Auto Synchronizing System


    Generator Set Output Cabinet


    Control Panel

    Czech·ComAp

    STND

    China·Hidier


    Denmark·Deif


    U.K.·Deepsea


    Voltages

    415/240V


    400/230V


    380/220V


    220/127V


    200-115V



    Quality 1800KW Automatic Control Panel Perkins Diesel Generators 4-Stroke for sale
    Send your message to this supplier
     
    *From:
    *To: Hidier Power Group (Beijing) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0