Bare Copper Wire Fire Alarm Cable 1x2x2.5 Unshielded 2 Core for Fire Protection Systems
#detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family:Roboto;font-size:24px;color:#53647a;font-style:normal;border-bottom-width:2px;padding-top:8px;padding-bottom:4px}#detail_decorate_root .magic-1{width:750px}#......
Ningbo Exact Cables & Wire Co., Ltd.
|
CSS2166 Addressable Fire Alarm Panel 100 dB Conventional Fire Alarm Horn Strobe
wired Siren For Addressable Fire Alarm System Fire Alarm Horn Strobe CSS2166 Conventional Fire Alarm Horn Strobe OVERVIEW AW-CSS2166-2 Fire Strobe Sounder is a kind of terminal device for alarm; it is used for the sound and light alarm when the fire happens. FEATURES & BENEFITS Adopt the two-wire or the four-wire system wiring method The main line end receives two main lines, No polarization Connect the power end to DC24V power line. PROJECT Fire...
Beijing HiYi Technology Co., Ltd
|
2 Wired 4 Wired Fire Alarm Heat Detector Temperature Fire Alarm Infrared Type
...Wired 4 Wired Conventional Heat Detector Temperature Fire Alarm Features 1. Smart adopted, high stability 2. Low standby current 3. Anti-RFI & Anti-EMI 4. 9~35VDC wide voltage 5. Duel LED for 360 visual 6. Flashing LED power indicator Technical Data: Type 2 wires 4 wires Voltage DC 9V~35V Standby current ≤55uA Alarm current ≤55mA@DC24V ≤25mA@DC24V Alarm indication Red LED Flash Reset Power Off Temperature -10℃ +50℃ Humidity ≤95 RH Alarm......
Mantern Industrial Co., Ltd.
|
OEM Practical 3 Core Fire Alarm Cable , Anti Alkali Fire Alarm Electrical Wire
...alarm system wiring cable NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems, including all circutis controlled and powered by the fire alarm system. These systems are defined in the NEC as " The portion of wiring......
Haiyan Hetai Cable Co., Ltd.
|
Automatic Fire Protection Systems Fire Alarm Signal Automatic
... the output control module starts the alarm, it is ringing alarm signal to inform the proximate persons of the need to take action, usually to evacuate. Working principle : When a fire occurs, smoke in the air contained in the particle concentration and...
Guangzhou Xingjin Fire Equipment Co.,Ltd.
|
BS6387 Standard Fire Alarm Cable Stranded Class 5 AWG Halogen Free
...Fire alarm Cable Stranded Class 5 AWG Thermoplastic Low Smoke, Halogen Free BS6387 Fire alarm Cable AWG Cable Construction : Conductor: Plain annealed copper wire, Stranded Class 5 Insulation: Special mix silicon rubber Shield: Aluminum/ PETP tape over 0.4mm tinned copper drain wire......
HANGZHOU ZION COMMUNICATION CO., LTD
|
120dB Fire Alarm Equipment Aluminum Alloy Fire Detection Alarm
..., making it lightweight and durable. The weight of the equipment is only 3kg, making it easy to install and use. The sound pressure level of this Fire Alarm Equipment can reach up to 120dB, which is loud enough to alert people in the building. It can be...
Shandong Jvante Fire Protection Technology Co., Ltd.
|
PH120 Standard Bare Copper Shielded Fireproof Electrical Wire , Fire Alarm Cable 2 Core 1.5mm
...m 0.2 to 2.5mm2,with the isolation of fire-resistant silicone rubber sheathed in PVC low flammability with low smoke and gas evolution.The shell is orange. Designed for group use,fixed installations in fire protection systems,including fire alarm systems...
Shenzhen Jinhuanyu Wire and Cable Co., Ltd
|
FRC LSZH House Wiring Fire Resistant Cable 300 / 500V IEC60332 IEC60228 IEC60331
...Wiring Cable 300/500V IEC60332 ,IEC60228,IEC60331 Standards International: IEC 60227 China: GB/T 5023-2008 Other standards such as BS,DIN and ICEA upon request Technical data Rated voltage:300/500 V, 300/300V, 450/750V Max. Conductor Temp. in normal use: 70°C or 90°C Certificates CE, RoHS, CCC, KEMA and more others at request Fire Resistant Fire Alarm Cables 225V SR Insulated & LSZH Sheathed Fire Alarm......
Shanghai Shenghua Cable (Group) Co., Ltd.
|
Wired conventional fire alarm system with 8 zones
...Wired conventional fire alarm system with 8 zones 8 zones wired fire alarm system for conventional Model:JS-FAS02 Conventional Fire Alarm 1.4 zones, 8 zones, 16 zones for choice; 2.2 Sound Output Conventional Fire Alarm Control panel: 3.4( 8 or 16) Style B (Class B) Initiating Device Circuits (IDCs). 4. All zones accept two-wire......
JSUS ELECTRONIC TECHNOLOGY CO.,LIMITED
|