Sign In | Join Free | My chinalane.org
chinalane.org
Products
Search by Category
Home >

HF2016.5 Cross-Type Membrane Valve Trocar The Top Choice for Laparoscopic Instruments

Categories Laparoscopic Surgical Instruments
Model NO.: HF2016.5
HS Code: 9018909010
Supply Ability: 500 PCS/Month
OEM: Yes
Transport Package: Standard Export Packing
Specification: Steel
Trademark: Vanhe
Origin: Tonglu, Zhejiang, China
Customization: Available | Customized Request
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

HF2016.5 Cross-Type Membrane Valve Trocar The Top Choice for Laparoscopic Instruments

1. Trocar Details:
ModelNameSpecifications
HF2016.12Magnetic flap valve trocarΦ5.5mm
HF2016.13Magnetic flap valve trocarΦ10.5mm
HF2016.14Magnetic flap valve trocarΦ11mm
HF2016.15Magnetic flap valve trocarΦ6mm
HF2016.16Magnetic flap valve trocarΦ12.5mm
HF2016.20Magnetic flap valve trocar with protection, bloodlessΦ5.5mm
HF2016.21Magnetic flap valve trocar with protection, bloodlessΦ6mm
HF2016.22Magnetic flap valve trocar with protection, bloodlessΦ10.5mm
HF2016.23Magnetic flap valve trocar with protection, bloodlessΦ11mm
HF2016.38Magnetic flap valve trocar with protection, bloodlessΦ12.5mm
HF2016.17Magnetic flap valve trocar with retaining threadΦ5.5mm
HF2016.18Magnetic flap valve trocar with retaining threadΦ10.5mm
HF2016.24Magnetic flap valve trocar with retaining threadΦ6mm
HF2016.25Magnetic flap valve trocar with retaining threadΦ12.5mm
HF2016.35Magnetic flap valve trocar with retaining threadΦ11.5mm
HF2016.30Magnetic flap valve trocar with protection, retaining threadΦ5.5mm
HF2016.31Magnetic flap valve trocar with protection, retaining threadΦ10.5mm
HF2016.32Magnetic flap valve trocar with protection, retaining threadΦ6mm
HF2016.33Magnetic flap valve trocar with protection, retaining threadΦ12.5mm
HF2016.34Magnetic flap valve trocar with protection, retaining threadΦ11mm
HF2016.65Trumpet trocarΦ10.5mm
HF2016.66Trumpet trocarΦ5.5mm
HF2016.67Trumpet trocar with protectionΦ10.5mm
HF2016.68Trumpet trocar with protectionΦ5.5mm
HF2016.5Cross-type trocarΦ10.5mm
HF2016.6Cross-type trocarΦ5.5mm
HF2016.8Cross-type trocarΦ11mm
HF2016.9Cross-type trocarΦ12.5mm
HF2016.10Cross-type trocarΦ6mm
HF2016.3Cross-type trocar with protectionΦ10.5mm
HF2016.4Cross-type trocar with protectionΦ5.5mm
HF2016.7Cross-type trocar with protectionΦ11mm
HF2016.28Cross-type trocar with protectionΦ6mm
HF2016.29Cross-type trocar with protectionΦ12.5mm
HF2016.3ACross-type trocar with retaining threadΦ10.5mm
HF2016.4ACross-type trocar with retaining threadΦ5.5mm
HF2016.36Cross-type trocar with protection, retaining threadΦ10.5mm
HF2016.37Cross-type trocar with protection, retaining threadΦ5.5mm

2. Accessories:
HF2017.1Adaptor/ReducerΦ10.5-5.5mm
HF2017.2Adaptor/Reducer, stainless, long tubeΦ10.5-5.5mm
HF2017.4Adaptor/Reducer, stainless, long tubeΦ5-3mm
HF2017.5Adaptor/Reducer, plasticΦ10.5-5.5mm
HF6002.1Sealing capΦ5mm
HF6002.2Sealing capΦ10.5mm
HF6002.3Sealing capΦ12.5mm
HF6001.1Cross-type membrance valveΦ5mm
HF6001.2Cross-type membrance valveΦ10mm
HF6003.2O-ringΦ10.5mm
HF6003.3O-ringΦ5.5mm


3 Packing & Shipping:
Package detail:Poly bag and special shockproof paper box.
Delivery detail:By air

Cross-Type Membrance Valve Trocar of Laparoscopic InstrumentsCross-Type Membrance Valve Trocar of Laparoscopic InstrumentsCross-Type Membrance Valve Trocar of Laparoscopic InstrumentsCross-Type Membrance Valve Trocar of Laparoscopic InstrumentsCross-Type Membrance Valve Trocar of Laparoscopic InstrumentsCross-Type Membrance Valve Trocar of Laparoscopic Instruments


FAQ




What types of staplers are used in minimally invasive surgery?


There are many types of staplers used in minimally invasive surgery, mainly including the following:


Cutting stapler: This instrument can cut and sew tissues at the same time, is flexible to use, and is suitable for a variety of surgeries.
These staplers provide a variety of options according to different surgical needs and usage methods to meet the needs of various minimally invasive surgeries.


What are the specific types and application scenarios of endoscopic staplers in minimally invasive surgery?


The specific types and application scenarios of endoscopic staplers in minimally invasive surgery are as follows:


Type:

Endoscopic stapler (without stapler): This type of endoscopic stapler is mainly used for tissue or blood vessel severance, resection and/or anastomosis.
Metal clip: This is one of the most commonly used endoscopic suturing instruments, usually used in endoscopic minimally invasive treatment.


Application scenario:

Laparoscopic surgery: some fine directional operations are completed under laparoscopy, such as manual suturing operations, fine anastomosis operations, etc.
Urological surgery: used for laparoscopic surgery of the upper urinary tract in urological surgery. Physicians use the master-slave control system to control minimally invasive surgery, and surgical instruments assist in surgical cutting, suturing, clamping and other tasks.



What are the technical characteristics and advantages of cutting staplers in minimally invasive surgery?


The technical characteristics and advantages of cutting staplers in minimally invasive surgery are mainly reflected in the following aspects:


Simple and precise operation: The operation process of the cutting stapler is simple, and it can achieve high-precision cutting and suturing, ensuring the stability and safety of the surgical process.


Improve surgical efficiency: Instead of traditional manual suturing methods, cutting staplers can significantly improve the suturing and cutting efficiency of surgical operations, especially in open surgery.


Reduce complications: Some specific cutting staplers use cold knife cutting technology to avoid complications that may be caused by the use of electric knives, thereby reducing the patient's postoperative risks.


Compared with traditional staplers, what are the significant improvements or advantages of disposable minimally invasive laparoscopic cutting staplers?


Compared with traditional staplers, disposable minimally invasive laparoscopic cutting staplers have the following significant improvements or advantages:


The blade is always sharp: The disposable cutting blade is replaced at the same time as the component to ensure that the blade always remains sharp, thereby achieving more complete tissue cutting and reducing tissue damage.



How is the use method and effect evaluation of skin staplers (skin staplers) in minimally invasive surgery?


The use method and effect evaluation of skin staplers (skin staplers) in minimally invasive surgery are as follows:


Usage method
Align the incision: Align the stapler head with the wound, and the front end is close to the skin.


Effect evaluation
Good healing effect: Skin staplers can effectively promote wound healing in minimally invasive surgery, with fast healing speed and good postoperative recovery.


Reduce pain: Due to the small surgical incision and less pain, the patient's postoperative recovery is relatively smooth.


High safety: Disposable skin staplers avoid the risk of cross infection and improve the safety of surgery.


The use method of skin staplers in minimally invasive surgery includes routine disinfection, pulling the skin together, aligning the incision and applying uniform force.


Classification of minimally invasive fascial closure devices and their application and effect evaluation in laparoscopic surgery.


Minimally invasive fascial closure devices are mainly used in laparoscopic surgery to prevent postoperative complications by suturing the incision. The classification and application of minimally invasive fascial closure devices are as follows:


Classification
The main components include suturing frames and suturing needles, where the suturing frames are made of ABS material and the needles are made of 304 stainless steel.


Application
Application in laparoscopic surgery:


Effect evaluation:

Summary
As a disposable medical device, minimally invasive fascial closure devices are mainly used to close incisions in laparoscopic surgery.


For more photos and details please contact me:
Company Name: Tonglu Wanhe Medical Instruments Co., Ltd.
Sales: Sue

Quality HF2016.5 Cross-Type Membrane Valve Trocar The Top Choice for Laparoscopic Instruments for sale
Send your message to this supplier
 
*From:
*To: Tonglu Wanhe Medical Instrument Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0