SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1

Categories PLC SIMATIC S7-400
Brand Name: SIEMENS
Model Number: 6ES7412-1XJ05-0AB0
Certification: CE
Place of Origin: GERMANY
MOQ: 1
Price: USD
Payment Terms: L/C, T/T
Supply Ability: 10PS
Delivery Time: 5-10DAYS
Packaging Details: 30*20*4
CPU: S7-400
Communication: Ethernet, Profibus, Profinet, MPI, and more
Dimensions: 145 x 90 x 140 mm
Memory: Up to 512 KB
Mounting: Rack-mounted
Operating temperature: 0°C to 60°C
Power supply: 24 V DC
Product name: PLC SIMATIC S7-400
Programming environment: STEP 7
Programming language: Ladder logic, Function block diagram, Structured text, Sequential function chart
Protection class: IP20
Type: Programmable Logic Controller
Weight: 0.7 kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1


Product Name: SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1


Introduction:

The SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1 is a powerful programmable logic controller designed for large and complex automation applications. It is part of the SIEMENS SIMATIC S7-400 series, which offers high-performance control and communication capabilities for demanding industrial environments.


Origin: Germany


Product Specifications:

- Product Name: SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1

- CPU Type: 412-1

- Compatibility: SIEMENS SIMATIC S7-400 series

- Number of Digital Inputs: Varies depending on configuration

- Number of Digital Outputs: Varies depending on configuration

- Number of Analog Inputs: Varies depending on configuration

- Number of Analog Outputs: Varies depending on configuration

- Communication Ports: Multiple communication interfaces (e.g., Ethernet, PROFIBUS, MPI)

- Memory: Varies depending on configuration

- Operating Temperature: 0 to 60°C

- Dimensions (W x H x D): Varies depending on the module

- Weight: Varies depending on the module


Product Features:

- High-performance CPU for large and complex automation applications

- Compatible with the SIEMENS SIMATIC S7-400 series

- Supports a wide range of digital and analog inputs and outputs

- Multiple communication interfaces for seamless integration into industrial networks

- Flexible memory configuration to accommodate specific application requirements

- Robust construction and reliable performance for demanding industrial environments

- Easy programming and configuration using the STEP 7 programming software


Functionality:

- The SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1 is designed to provide high-performance control and communication capabilities for large and complex automation applications.

- It is compatible with the SIEMENS SIMATIC S7-400 series, allowing for seamless integration with other modules and components.

- The CPU supports a wide range of digital and analog inputs and outputs, providing flexibility for various automation requirements.

- Multiple communication interfaces (such as Ethernet, PROFIBUS, and MPI) enable easy connectivity to other devices and networks.

- The memory configuration can be customized to accommodate specific application requirements.

- With its robust construction and reliable performance, the CPU is suitable for demanding industrial environments.

- Programming and configuration can be done using the STEP 7 programming software, which offers a user-friendly interface for efficient development and maintenance.


Please note that for more detailed technical specifications and information, it is recommended to refer to the official documentation or contact Siemens directly.



********** Replacement part ********* SIMATIC S7-400, CPU 412-1 Central processing unit with: work memory 288 KB, (144 KB code, 144 KB of data), Interface MPI/DP 12 Mbit/s,
General information
Product type designationCPU 412-1
HW functional status03
Firmware versionV5.3
Product function
● Isochronous modeYes; For PROFIBUS only
Engineering with
● Programming packageSTEP 7 V5.3 SP2 or higher with HW update
CiR - Configuration in RUN
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte30 µs
Supply voltage
Rated value (DC)Power supply via system power supply
Input current
from backplane bus 5 V DC, typ.0.5 A
from backplane bus 5 V DC, max.0.6 A
from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface
from interface 5 V DC, max.90 mA
Power loss
Power loss, typ.2.5 W
Power loss, max.3 W
Memory
Type of memoryRAM
Work memory
● integrated288 kbyte
● integrated (for program)144 kbyte
● integrated (for data)144 kbyte
● expandableNo
Load memory
● expandable FEPROMYes; with Memory Card (FLASH)
● expandable FEPROM, max.64 Mbyte
● integrated RAM, max.512 kbyte
● expandable RAMYes; with Memory Card (RAM)
● expandable RAM, max.64 Mbyte
Backup
● presentYes
● with batteryYes; all data
● without batteryNo
Battery
Backup battery
● Backup current, typ.125 µA; up to 40 °C
● Backup current, max.300 µA
● Backup time, max.See reference manual, module data, Chapter 3.3
● Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times
for bit operations, typ.75 ns
for word operations, typ.75 ns
for fixed point arithmetic, typ.75 ns
for floating point arithmetic, typ.225 ns
CPU-blocks
DB
● Number, max.1 500; Number range: 1 to 16000
● Size, max.64 kbyte
FB
● Number, max.750; Number range: 0 to 7999
● Size, max.64 kbyte
FC
● Number, max.750; Number range: 0 to 7999
● Size, max.64 kbyte
OB
● Number, max.see instruction list
● Size, max.64 kbyte
● Number of free cycle OBs1; OB 1
● Number of time alarm OBs2; OB 10, 11
● Number of delay alarm OBs2; OB 20, 21
● Number of cyclic interrupt OBs2; OB 32, 35 (shortest cycle that can be set = 500 µs)
● Number of process alarm OBs2; OB 40, 41
● Number of DPV1 alarm OBs3; OB 55-57
● Number of isochronous mode OBs2; OB 61-62
● Number of multicomputing OBs1; OB 60
● Number of background OBs1; OB 90
● Number of startup OBs3; OB 100-102
● Number of asynchronous error OBs9; OB 80-88
● Number of synchronous error OBs2; OB 121, 122
Nesting depth
● per priority class24
● additional within an error OB1
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
S7 times
● Number2 048
Retentivity
— adjustableYes
— presetNo times retentive
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
Flag
● Size, max.4 kbyte; Size of bit memory address area
● Retentivity availableYes
● Retentivity presetMB 0 to MB 15
● Number of clock memories8; in 1 memory byte
Local data
● adjustable, max.8 kbyte
● preset4 kbyte
Address area
I/O address area
● Inputs4 kbyte
● Outputs4 kbyte
Process image
● Inputs, adjustable4 kbyte
● Outputs, adjustable4 kbyte
● Inputs, default128 byte
● Outputs, default128 byte
● consistent data, max.244 byte
● Access to consistent data in process imageYes
Subprocess images
● Number of subprocess images, max.15
Digital channels
● Inputs32 768
— of which central32 768
● Outputs32 768
— of which central32 768
Analog channels
● Inputs2 048
— of which central2 048
● Outputs2 048
— of which central2 048
Hardware configuration
Integrated power supplyNo
Number of expansion units, max.21
connectable OPs31
MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
Interface modules
● Number of connectable IMs (total), max.6
● Number of connectable IM 460s, max.6
● Number of connectable IM 463s, max.4; IM 463-2
Number of DP masters
● integrated1
● via CP10; CP 443-5 Extended
● via IM 4674
● Mixed mode IM + CP permittedNo; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
● via interface module0
● Number of pluggable S5 modules (via adapter capsule in central device), max.6
Number of IO Controllers
● integrated0
● via CP4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended)
● FMLimited by number of slots and number of connections
● CP, PtPCP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
● PROFIBUS and Ethernet CPs14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum
Slots
● required slots1
Time of day
Clock
● Hardware clock (real-time)Yes
● retentive and synchronizableYes
● Resolution1 ms
● Deviation per day (buffered), max.1.7 s; Power off
● Deviation per day (unbuffered), max.8.6 s; For power On
Operating hours counter
● Number16
● Number/Number range0 to 15
● Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
● Granularity1 h
● retentiveYes
Clock synchronization
● supportedYes
● to MPI, masterYes
● to MPI, slaveYes
● to DP, masterYes
● to DP, slaveYes
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPNo; Via CP
● to IF 964 DPNo
Time difference in system when synchronizing via
● MPI, max.200 ms
Interfaces
Interfaces/bus type1 x MPI/PROFIBUS DP
Number of RS 485 interfaces1; Combined MPI / PROFIBUS DP
Optical interfaceNo
1. Interface
Interface typeMPI/PROFIBUS DP
IsolatedYes
Interface types
● RS 485Yes
● Output current of the interface, max.150 mA
Protocols
● MPIYes
● PROFIBUS DP masterYes
● PROFIBUS DP slaveYes
MPI
● Number of connections32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
PROFIBUS DP master
● Number of connections, max.16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max.12 Mbit/s
● Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes; S7 routing
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV1Yes
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP slave
— User data per DP slave, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP slave
● Number of connections16
● GSD filehttp://support.automation.siemens.com/WW/view/en/113652
● Transmission rate, max.12 Mbit/s
● automatic baud rate searchNo
● Address area, max.32; Virtual slots
● User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— PG/OP communicationYes; with interface active
— RoutingYes; with interface active
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— Direct data exchange (slave-to-slave communication)No
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
Protocols
Open IE communication
● ISO-on-TCP (RFC1006)Via CP 443-1 Adv. and loadable FB
— Data length, max.1 452 bytes via CP 443-1 Adv.
Web server
● supportedNo
Isochronous mode
EquidistanceYes
Number of DP masters with isochronous mode1
User data per isochronous slave, max.244 byte
shortest clock pulse1.5 ms; 0.5 ms without use of SFC 126, 127
max. cycle32 ms
communication functions / header
PG/OP communicationYes
● Number of connectable OPs without message processing31
● Number of connectable OPs with message processing31; When using Alarm_S/SQ and Alarm_D/DQ
Data record routingYes
Global data communication
● supportedYes
● Number of GD loops, max.8
● Number of GD packets, transmitter, max.8
● Number of GD packets, receiver, max.16
● Size of GD packets, max.54 byte
● Size of GD packet (of which consistent), max.1 variable
S7 basic communication
● communication function / S7 basic communicationYes
● User data per job, max.76 byte
● User data per job (of which consistent), max.1 variable
S7 communication
● supportedYes
● as serverYes
● as clientYes
● User data per job, max.64 kbyte
● User data per job (of which consistent), max.462 byte
S5 compatible communication
● supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
● User data per job, max.8 kbyte
● User data per job (of which consistent), max.240 byte
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
Standard communication (FMS)
● supportedYes; Via CP and loadable FB
Number of connections
● overall32
● usable for PG communication31
— reserved for PG communication1
— adjustable for PG communication, max.0
● usable for OP communication31
— reserved for OP communication1
— adjustable for OP communication, max.0
● usable for S7 basic communication30
— reserved for S7 basic communication0
— adjustable for S7 basic communication, max.0
● usable for S7 communication30
— reserved for S7 communication0
— adjustable for S7 communication, max.0
● usable for routing15
— reserved for routing0
— adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.31; Max. 31 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm_8 and Alarm_P (e.g. WinCC)
Symbol-related messagesYes
SCAN procedureYes
Program alarmsYes
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocksYes
● Number of instances for alarm 8 and S7 communication blocks, max.300
● preset, max.150
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)4
Number of messages
● overall, max.256
● in 100 ms grid, max.0
● in 500 ms grid, max.256
● in 1000 ms grid, max.256
Number of additional values
● with 100 ms grid, max.0
● with 500, 1000 ms grid, max.1
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control
● Status/control variableYes; Up to 16 variable tables
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.70; Status/control
Forcing
● ForcingYes
● Forcing, variablesInputs/outputs, bit memories, distributed I/Os
● Number of variables, max.64
Diagnostic buffer
● presentYes
● Number of entries, max.200
— adjustableYes
— preset120
Service data
● can be read outYes
Standards, approvals, certificates
CE markYes
CSA approvalYes
UL approvalYes
cULusYes
FM approvalYes
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
Use in hazardous areas
● ATEXATEX II 3G Ex nA IIC T4 Gc
Ambient conditions
Ambient temperature during operation
● min.0 °C
● max.60 °C
configuration / header
Configuration software
● STEP 7Yes
configuration / programming / header
● Command setsee instruction list
● Nesting levels7
● Access to consistent data in process imageYes
● System functions (SFC)see instruction list
● System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
configuration / programming / number of simultaneously active SFC / header
— DPSYC_FR2; SFC 11; per interface
— D_ACT_DP8; SFC 12; per interface
— RD_REC8; SFC 59; per interface
— WR_REC8; SFC 58; per interface
— WR_PARM8; SFC 55; per interface
— PARM_MOD1; SFC 57; per interface
— WR_DPARM2; SFC 56; per interface
— DPNRM_DG8; SFC 13; per interface
— RDSYSST8; SFC 51
— DP_TOPOL1; SFC 103; per interface
configuration / programming / number of simultaneously active SFB / header
— RDREC8; SFB 52; per interface, but not more than 32 across all external interfaces
— WRREC8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
● User program protection/password protectionYes
Dimensions
Width25 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.700 g
Quality SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0  CPU 412-1 for sale
Send your message to this supplier
 
*From:
*To: Shenzhen Voboal Industrial Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0